|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Series HA60/HD60 25-125Amp * 600 Vac * AC Output * Zero Voltage and Random Turn-On Switching * Panel Mount * 1200V Blocking Capability * 600Vac - the preferred choice in Canada Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turn-on (phase controllable) and versions with either AC or DC input (coil) control. Manufactured in Crydom's ISO 9002 Certified facility for optimum product performance and reliability. HA6090 HD6090 600 48-660 90 40 1200 1,200 1.7 0.28 6,000 5 500 HA60125 HD60125 600 48-660 125 150 1200 1,750 1.7 0.22 12,700 5 500 MODEL NUMBERS AC CONTROL D C C ONTROL HA6025 HD6025 600 48-660 25 40 1200 250 1.7 1.02 260 5 500 HA6050 HD6050 600 48-660 50 40 1200 625 1.7 0.63 1,620 5 500 OUTPUT SPECIFICATIONS Nominal Line Voltage (10%) [Vrms] Operating Voltage Range (47-63 Hz) [Vrms] Max. Load Current [Arms] Min. Load Current, [mArms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (RJC) [C/W] Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/sec] Max. Turn-On Time Max. Turn-Off Time Power Factor (Min.) with Max. Load 1/2 Cycle (DC Input), 10.0 msec (AC Input) 1/2 Cycle (DC Input), 40.0 msec (AC Input) 0.5 0.5 0.5 0.5 INPUT SPECIFICATIONS Control Voltage Range Max. Reverse Voltage Max. Turn-On Voltage Min. Turn-Off Voltage Nominal Input Impedance Typical Input Current DC CONTROL (D PREFIX) AC CONTROL (A PREFIX) 90-280 Vrms (60Hz) --90 Vrms 10 Vrms 60K Ohms 2mA @ 120 Vrms, 4mA @ 240 Vrms AC CONTROL (E SUFFIX) 3-32 Vdc -32 Vdc 3.0 Vdc 1.0 Vdc See Note 2.0 mA 18-36 Vrms --18 Vrms 4.0 Vrms 9.0K Ohms 3mA @ 24 Vrms GENERAL NOTES (c)1998 CRYDOM CORP, Specifications subject to change without notice. All parameters at 25C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Heat sinking required, for derating curves see page 2. 24 Vac Input option, E suffix. Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). Input circuitry incorporates active current limiter. For recommended applications and more information contact: No internal snubber. USA: (800) 8 CRYDOM * (800) 827-9366 * (619) 715-7200 * fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 * e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 * fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 * fax (49)(0)6874 182585 Crydom GmbH, Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany * e-mail: vertrieb@crydom.com FastFax Document No.159 SERIES HA/HD60.032698, PAGE 1 OF 3 Series HA60/HD60 25-125Amp * 600 Vac * AC Output GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: Terminals: AVAILABLE OPTIONS E -10 24 VAC Input (18-36 Vac) Example: HA6025E Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: HD6090-10 Faston Terminals (Up to 50 Amp Models) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1.10 (27.9) .45 (11.4) 4000 Vrms 109 Ohm 8 pF -40 to 80C -40 to 125C 3.0 oz. (86.5g) Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted 8-32 TERMINAL (2 PLACES ) 1 OUTPUT 2 F 1.87 (47.5) SOLID-STATE RELAY -4 INPUT + 3 2.30 (58.4) 1.70 (43.2) BASE PLATE .125 (3.2) 1.00 (25.4) 1.80 (45.7) 6-32 TERMINAL (2 PLACES) .78 (19.8) .90 (22.9) Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1.10 (27.9) .45 (11.4) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 1 OUTPUT 2 1.87 (47.5) 4 INPUT 3 2.30 (58.4) 1.70 (43.2) Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. BASE PLATE .125 (3.2) 1.00 (25.4) 1.80 (45.7) FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) (c)1998 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116950 CSA LR81689 VDE 10143 UG FastFax Document No.159 SERIES HA/HD60.032698, PAGE 2 OF 3 For recommended applications and more information contact: USA: (800) 8 CRYDOM * (800) 827-9366 * (619) 715-7200 * fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 * e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 * fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 * fax (49)(0)6874 182585 Crydom GmbH, Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany * e-mail: vertrieb@crydom.com Series HA60/HD60 25-125Amp * 600 Vac * AC Output CURRENT DERATING CURVES 25A 30 1C/W Base Plate Temp [C] 50A 95 3C/W 2C/W 60 1C/W .5C/W 90 Base Plate Temp [C] Base Plate Temp [C] 25 Power Dissipation 100 Power Dissipation 1.5C/W 20 15 10 5 0 5 10 15 20 25 40 2C/W 100 110 20 NO HEATSINK 110 NO HEATSINK 120 0 20 40 60 80 10 20 30 40 120 80 50 20 40 60 Load Current [Arms] Max Ambient Temp. [C] Load Current [Arms] Max Ambient Temp. [C] 90A 120 .5C/W Power Dissipation 90 .2C/W Power Dissipation 125A 160 .4C/W Base Plate Temp [C] 90 .5C/W .2C/W 100 .4C/W 80 1C/W 100 120 80 110 40 120 0 20 40 60 80 0 20 40 60 80 Load Current [Arms] Max Ambient Temp. [C] 1C/W 110 40 120 0 30 60 90 120 0 20 40 60 80 Load Current [Arms] Max Ambient Temp. [C] (c)1998 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No.159 SERIES HA/HD60.032698, PAGE 3 OF 3 For recommended applications and more information contact: USA: (800) 8 CRYDOM * (800) 827-9366 * (619) 715-7200 * fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 * e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 * fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 * fax (49)(0)6874 182585 Crydom GmbH, Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany * e-mail: vertrieb@crydom.com |
Price & Availability of HD6050-E |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |